 Click image above for more info


|
125 kHz ThinLine II Reader
|
|
|
Product ID: 5395
Providing performance and reliability, HID's attractive, unobtrusive ThinLine II proximity card reader is housed in a two-piece, weatherproof secure potted enclosure. - The size of most standard U.S. switch plates.
- Available with Wiegand or Clock-and-Data interface.
- Potted reader suitable for indoor or outdoor use.
- Base part numbers: 5395 (Wiegand), 5398 (Clock-and-Data).
- 18" (45 cm) wire pigtail standard; consult factory for 9' (2.7 m) pigtail available by special order.
Features
- Easily installed and maintained with the use of replaceable covers.
- Available with a Wiegand or Clock-and-Data interface.
- Provides high reliability, consistent read range and low power consumption.
- Features include multicolor LED and internal control or host control of the LED and beeper.
- Mounts directly on metal with minimal impact on the read range performance.
- Aesthetic design available in two cover designs and four colors to match any décor.
- Includes multilingual installation manual.
Specifications:
- Typical maximum* read range
o ProxCard® II Card - up to 5.5" (14 cm) o ISOProx® II Card - up to 5" (12.7 cm) o DuoProx® II Card - up to 5" (12.7 cm) o Smart ISOProx®/DuoProx® cards - up to 5" (12.7 cm) o Proximity & MIFARE® Card - up to 5" (12.7 cm) o ProxCard Plus® Card - up to 1.5" (3.8 cm) o ProxKey® II Keyfob - up to 2" (5.1 cm) o MicroProx® Tag - up to 3" (7.6 cm) *Depending on local installation conditions. - Dimensions
o 4.70" x 3.00" x 0.68" (11.9 x 7.6 x 1.7 cm) - Power Supply
o 5-16 VDC o Linear power supplies are recommended. - Maximum Current Requirements
o Average: 30 mA (5 VDC); 20 mA (12 VDC) o Peak: 110 mA (5 VDC); 110 mA (12 VDC) - Operating Temperature
o -22° to 150° F (-30° to 65° C) - Operating Humidity
o 0-95% relative humidity noncondensing - Weight
o 3.3 oz. (94 gm) - Cable Distance
o Wiegand interface: 500 feet (150 m) o Clock-and-data interface: 50 feet (15 m) o Recommended cable is ALPHA 1295 (22 AWG) o 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control. - Certifications
o Canada/UL 294 Listed: Access Control System Units Canada/UL 1604 Listed (with Haz. Loc. junction box only): Hazardous Locations Class I, Div. 2, Groups A,B,C,D. o FCC Certification, United States o Canada Certification o EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety) o Fifteen EU Countries under the R&TTE Directive (EN 300330 - SRD, and ETS 300 683 - EMC) o CE Mark o Australia C-Tick o New Zealand o Taiwan, China
|
|
|
|
|
|